Technical data
Hydraulic Operating pressure max.: 315 bar (with free return flow in port 2) with aluminium manifolds 210 bar max. pressure at port 2: 35 bar
Flow rate: 80 l/min
Pressure setting range see type code
Flow direction: 1 (P) to 2 (T) (2 to 1 not allowed)
Hydraulic fluid: mineral oil according to DIN 51524,
others upon request Viscosity range: 10 - 350 cSt
Filtration: oil cleanliness according to ISO 4406 (1999) 18/16/13, filter with β 5(c) > 200
Repeatability: < 3% with optimized PWM-signal*
Hysteresis: < 5% with optimized PWM-signal
Mechanic
Design: EEPDBS screw-in valve T-10A or EEPDBM screw-in valve C-10-2, EPDBSA screw-in valve in mounting plate NG 6, pilot operated
Size: 08 Fluid temperature: -25 °C to +70 °C
Ambient temperature: -25 °C to +50 °C
Storage temperature: -30 °C to +60 °C (non-condensing)
Electric
Nominal voltage: 12 V DC, 24 V DC
Nominal valve current: 1,7 A (12 V), 0,7 A (24 V)
Nominal resistance (R20): 4 Ω (12 V), 25 Ω (24 V)
Power consumption: 16 W at nominal valve
current Shifting time: 100% ED
Control command: PWM-signal PWM-
frequency: typically 140 Hz (depending on application)
Protection class: IP65 with correctly mounted and locked mating
connector Electric termination: Electric plug according to DIN EN 175301-803 (formerly DIN 43650) shape A, AMP Junior Timer, unterminated wire